NEC Express5800 Series Maintenance Manual page 127

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
B022
Serial Port Configuration
Overlapped.
PCI System Error on
B030
Bus/Device/Function
PCI Parity Error on
B040
Bus/Device/Function
Onboard LAN 1 – PCIe Link
B201
Failure
Onboard LAN 2 – PCIe Link
B202
Failure
PCI Slot 1 – PCIe Link
B211
Failure
PCI Slot 2 – PCIe Link
B212
Failure
Onboard LAN 1 – PCIe Link
B221
Width Error
Onboard LAN 2 – PCIe Link
B222
Width Error
B231
PCI Slot 1 - PCIE Link Width
Error
B232
PCI Slot 2 - PCIE Link Width
Error
Onboard LAN 1 – PCIe Link
B261
Speed Error
Onboard LAN 2 – PCIe Link
B262
Speed Error
B233
PCI Slot 3 - PCIE Link Width
Error
B234
PCI Slot 4 - PCIE Link Width
Error
B235
PCI Slot 5 - PCIE Link Width
Error
B271
PCI Slot 1 - PCIE Link Speed
Error
B272
PCI Slot 2 - PCIE Link Speed
Error
B273
PCI Slot 3 - PCIE Link Speed
Error
B274
PCI Slot 4 - PCIE Link Speed
Error
B275
PCI Slot 5 - PCIE Link Speed
Error
C000
The error occurred during
fan sensor reading.
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C041
SROM data checksum bad
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
Cause
Overlapping serial port configuration
was detected.
PCI SERR was detected.
PCI PERR was detected.
Connection failure of PCIe bus was
detected on onboard LAN1.
Connection failure of PCIe bus was
detected on onboard LAN2.
Connection failure of PCIe bus was
detected on PCI slot 1.
Connection failure of PCIe bus was
detected on PCI slot 2.
PCIe bus width error was detected
on onboard LAN1.
PCIe bus width error was detected
on onboard LAN2.
A Link Width error was detected in PCI
Slot 1.
A Link Width error was detected in PCI
Slot 2.
PCIe bus speed error was detected
on onboard LAN1.
PCIe bus speed error was detected
on onboard LAN2.
A Link Width error was detected in PCI
Slot 3.
A Link Width error was detected in PCI
Slot 4.
A Link Width error was detected in PCI
Slot 5.
A Link Speed error was detected in PCI
Slot 1.
A Link Speed error was detected in PCI
Slot 2.
A Link Speed error was detected in PCI
Slot 3.
A Link Speed error was detected in PCI
Slot 4.
A Link Speed error was detected in PCI
Slot 5.
An error was detected while reading
fan sensor.
An error was detected while reading
temperature sensor.
A temperature abnormality was
detected.
An error was detected while reading
voltage sensor.
A system voltage abnormality was
detected.
An error was detected while reading
data on SROM.
A checksum error was detected
while reading FRU data.
An error was detected on 1st SM Bus.
An error was detected on 2nd SM Bus.
An error was detected on 3rd SM Bus.
Express5800/E120d-1 Maintenance Guide
1. POST Error Message
Solution
Start SETUP, select Advanced  Serial Port
Configuration, and specify the setting again in a
way that the values of Base I/O or Interrupt in
Serial Port A and Serial Port B will not be the
same.
Contact your sales representative.
It is possible that a fan has failed or is clogged.
Contact your sales representative.
Contact your sales representative.
(4/6)
127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/e120d-1

Table of Contents