Mounting / Dismounting On An H−Rail - Festo MPA-F Series Description Pneumatics

Valve terminal
Hide thumbs Also See for MPA-F Series:
Table of Contents

Advertisement

2. Assembly
2.2.1 Mounting / dismounting on an H−rail
2−6
Caution
H−rails with mounted valve terminals can break if they are
subjected to vibration exceeding severity level 1:
0.15 mm path at 15 ... 85 Hz
2 g acceleration at 58 ... 150 Hz
This can damage the valve terminal, your machine or your
system.
In this case use wall mounting.
·
Note the permitted values for vibration and shock in
·
appendix A Technical data".
Caution
Hat−rail mounting without an H−rail clamping unit is not
permitted.
Secure the MPA−F valve terminal using the H−rail clamp
·
ing:
against sliding down with the retaining screw intended
for this purpose (see Tab. 2/2 and Fig. 2/1)
against unintentional releasing/opening.
In order to mount the valve terminal onto an H−rail you will
require the following mounting kits:
for MPA−F valve terminals with multi−pin plug connection:
CPA−BG−NRH. This kit contains 2 M4x10 screws and
2 clamping elements.
for MPA−F valve terminals with CPX terminal:
VMPAF−FB−BG−NRH. This set consists of 3 clamping com
ponents, two M4x12 screws and one M4x10 screw.
Festo P.BE−MPAF−EN en 0804NH

Advertisement