Siemens SICHARGE CC AC22-MID Operating Instructions Manual page 66

Hide thumbs Also See for SICHARGE CC AC22-MID:
Table of Contents

Advertisement

Status indicators
The following table provides an overview of status indicators of charging points:
SICHARGE Operating Instructions MID
Operating Instructions, 07/2020, A5E48573001-AB
Does not light up
If the status indicator does not light up, this indicates an
interruption to the power supply. If there is not a power
failure, check the backup fuses.
Lights up white
The controller is deactivated. The charge point is not availa-
ble.
Flashing white
Controller has been started. The charge point is not available
at the moment.
Lights up green
Charging of vehicles is possible.
Flashes green
No cable plugged in. Charging point is signing charging
process.
Lights up yellow
The charging point is connected to the vehicle.
No charging in progress.
Pulsating blue light
Charging process active:
The connected vehicle is receiving power.
Lights up blue
Charging inactive:
The connected vehicle is not drawing any power.
Flashing blue
Meter data for the charging process are being signed.
Flashes red 1x
Flashes red 2x
Contactor error
Flashes red 3x
Circuit breaker (CB) has tripped
Flashes red 4x
The residual current circuit breaker (RCCB) has tripped
Flashes red 5x
Connector lock error
Flashes red 6x
Meter error
Flashes red 7x
Vehicle error: Mode 3 unknown status
EVSE connection error
EV connection error
Excess temperature
Operation
6.1 Status indicators
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents