Technical specifications
Designation
Display
Connection voltage
Connection frequency
Maximum connected power
Load management acc. to maximum infeed, chronological
prioritization
Supported networks (local requirements to be clarified on site)
Maximum cross-section for cable
Weight (standard model)
Dimensions (H x W x D) in mm
Ambient temperature operating range
Humidity
Ambient air pressure
Protection rating (IP)
Intrinsic consumption in standard version
SIM card (recommended data volume)
Standards and legal bases:
EN 61851-1:2011
EN 61851-22:2002
EN 61000-6-3:2007+A1:2011
EN 61000-3-11:2000
EN 61000-3-12:2011
EN 61000-6-1:2007
IEC 62196-2
REA document 6-A / PTB-A 50.7 Legal reference to the Meas-
urement and Calibration Act of 25 July 2013
* If video functions are used, the data volume may have to be increased.
Times for full charging
Charging times depend on many variables, but mainly on the battery capacity of the vehicle.
To determine the time required for full charging of the vehicle, refer to the vehicle
documentation.
SICHARGE Operating Instructions MID
Operating Instructions, 07/2020, A5E48573001-AB
Technical specifications
12.1 Technical specifications
SICHARGE CC AC22
7" LED
AC 400 V ± 10%
3-phase
N+PE
50/60 Hz
63 A / phase
6 ... 63 A
TN-C / TN-S
TN-C-S/TT
35 mm
2
75 kg
1700 x 390 x 194
-25 ... 50 °C
5 ... 95%
860 ... 1060 hPa
IP 54
25 W
500 MB / month*
95