Sagem myC-4 Site Technical Documentation page 73

Hide thumbs Also See for myC-4:
Table of Contents

Advertisement

myC-4
4.32 Tools :
- Cross shaped screwdriver
- Gloves
- Metal dome Jig
- Tweezers
4.33 Preliminary operation
This procedure must be performed by a technician with gloves.
1. Remove the battery pack (
2. Remove the back cover (
4.34 Removal procedure :
1. Remove the metal dome (2) of the equipped electronic board (1)
4.35 Placement procedure :
Warning : The metal dome is not reusable, it must be necessarily replaced by a new metal dome,
unless the board is swapped and sent as level 3
1. Replace the new metal dome (2) on the equipped electronic board (1), using the metal dome jig.
4.36 Further operations :
1. Replace the back cover (
2. Replace the battery pack (
3. Carry out the radio test
Ref. SCT U38 SSC DTS 0023 – Index B - February 21, 2005
REMOVING / REPLACING THE METAL DOME
OF NUMBER KEYPAD
Proc sheet 0
01).
Proc sheet 1
02).
Proc sheet 1
02).
Proc sheet 0
01).
(Test Sheet
04).
Proc Sheet 1 04
1/2