8. ALARMS and DEFINITION
No
Title of Alarm
A1
Emergency Stop Button Pressed
A2
Low Air Pressure
A3
Electricity cut off
A4
Low oil level
A6
Door Open !
A12
Profile Feed Piston not retracted
(P1) !..
A13
Profile feed side piston not retracted
(P2) !..
A14
Wrong Profile Height !..
A15
Profile feed counter clamping piston
not retracted (P3) !..
A16
Wrong Profile Width !..
Definition
Emergency stop button is pressed.
Air deficiency
Phase is not supplied.
Lubricating oil is run out off.
Piston
may
not
completely.
If the piston is its back position,
sensor may not detect the piston.
Piston
may
not
completely.
If the piston is its forward position,
sensor may not detect the piston.
The entered profile dimension may
be wrong.
Encoder reads wrong value
Piston
may
not
completely.
If the piston is its back position,
sensor may not detect the piston.
The entered profile dimension may
be wrong.
Encoder reads wrong value.
Turn the button in clockwise direction
to release.
Check air conditioner whether air is
flowing.
Check compressor.
Check electricity distribution.
Check the power supply cables.
Check fuses.
Add oil.
come
back
Check valve of the piston or sensor.
If piston is not pushed forward, check
valve and air pipes.
push
forward
When the piston is its forward position
and sensor does not detect, adjust the
position of the sensor.
If sensor still does not identify the
piston, sensor may be broken.
If encoder reads wrong value, calibrate
the encoder.
come
back
Check valve of the piston or sensor.
If encoder reads wrong value, calibrate
the encoder.
Troubleshoot