 When 90 degrees is achieved, press on
button to confirm the process.
7.6.6 Calibration of 135 Degrees
 Enter 135 in
section and press on send button
 Place 135 degrees calibration apparatus between miter and saw as shown in below figure.
 If angle is bigger than 135
degrees, enter a smaller value than 135
degrees to target section and press on send button. If it is smaller than 135 degrees, enter a bigger value than 135 degrees
to target section.
 When 135 degrees is achieved, press on
button to confirm the process
7.6.7 Calibration of Profile Holding Robot on Y- Axis
 Before starting calibration of profile holding robot, define the reference of in Y- axis.
 Calibration of robot is performed by using the below screen.
 Enter the maximum allowable distance of robot on Y- axis in the below section.
 While robot is at reference position on Y- axis, measure the distance between zero point of profile along Y- axis and inside
the claw as shown in below figure.