Technical data
HP3a with 60 Hz operation
Type
Minimum pump capacity at maximum back pressure Maximum
bar
100010*
100
100021*
100
100025*
100
100031*
100
064019
64
064040
64
064048
64
064060
64
025048
25
025100
25
025120
25
025150
25
13.2

Metering reproducibility

80
psi
l/h
gph
1,450
12
3.2
1,450
25
6.6
1,450
30
7.9
1,450
37
9.8
928
23
6.1
928
48
12.7
928
58
15.3
928
72
19.0
362
58
15.3
362
120
31.7
362
144
38.0
362
180
47.6
* Material version SST / HCT with double ball valve
Alternatively double ball valve SST with RP 3/8
*** HV version G 1M - DN 15
*** HV version G 1 1/4M - DN 20
Maximum back pressure for liquid ends in material version PVT: 25 bar!
Maximum back pressure for liquid ends in material version TTT: 16 bar!
The metering capacity can deviate from the details above with HV ver‐
sions.
All figures refer to water at 20 °C.
Priming lift / priming pressure (dry) determined for empty suction line and
empty liquid end and as well as clean and moistened valves (the figures
are lower with valve springs).
The suction lift / suction pressure applies to filled suction lines and filled
liquid end - when installed correctly.
Data
Reproducibility
Suction
Permissible
stroke
lift
priming
rate
pressure,
suction side
Strokes/m
m water
bar
in
column
72
3
5
150
3
5
180
3
5
224
3
5
72
3
5
150
3
5
180
3
5
224
3
5
72
3
5
150
3
5
180
3
5
224
3
5
Connector
size
G-DN
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 3/4M -
DN10 **
G 1" - 10 ***
G 1" - 10 ***
G 1" - 10 ***
G 1" - 10 ***
Value Unit
±1 % *