HP StorageWorks Edge Switch 2/12 Installation Manual page 89

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Table 4: Switch Factory-Default Values for Reset Configuration Option (Continued)
Configuration
Operating Mode
Operating
Parameters
SNMP
Zoning
Edge Switch 2/12 Installation Guide
Description
Must select one of two modes:
Homogeneous mode or Open
Fabric 1.0. The recommended
mode is Open Fabric 1.0.
Preferred Domain ID
Insistent Domain ID
Rerouting Delay
Domain RSCN's
Suppress RSCN's on Zone set
activations
R_A_TOV
E_D_TOV
Switch Priority
SNMP Communities
SNMP Write Authorizations
Trap Recipient IP Addressees
UDP Port
SNMP Authorization Trap State
Number of Zone Members
Number of Zones
Number of Zone Sets
Zone Names
Zone Sets Names
Zone Members
Default Zone State
Active Zone Set State
Active Zone Set Name
Technical Specifications
Default
Open Fabric 1.0 mode
1
Disabled
Enabled
Disabled
Disabled
10 seconds (100 tenths)
2 seconds (20 tenths)
Default
"public" — 5 NULL strings
Read only per community
0 for each
162
disabled
0
0
0
None
None
None
Disabled
Disabled
NULL string