Installing and Configuring the Edge Switch 2/12
Figure 24: Security page—Port Binding tab
3. Click Activate to save the information. The message "Your changes to
64
a. Click the check box in the Port Binding column to enable or disable port
binding for a specified port (default is disabled).
b. In the Bound WWN column, enter the WWN of the device to which the
port is to be bound. If port binding is enabled, only the specified device
can connect to the port. If port binding is enabled and no device is
specified in the Bound WWN column, then no devices can connect to the
port.
c. The Attached WWN column contains read-only fields that list the
WWNs of attached Fibre Channel devices. Click the check box in the Use
Attached column to indicate the WWN specified in the Attached WWN
column is to be used for port binding. After activation, the attached WWN
displays in the Bound WWN column.
the port binding configuration have been
successfully activated" displays.