43
04
Fusing temperature setting 4
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 3.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table 3.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-4 FUSER TMP 4
1:TMPFIRST
2:TMPLAST
3:CNTFIRTS
Window display
1: TMPFIRST
2: TMPLAST
3: CNTFIRST
4: CNTTYPE1
5: CNTTYPE2
6: CNTTYPE3
*1, *2: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 3.)
*3: Correction temperature from starting a JOB to reaching the JOB initial temperature correction number
of sheets
*4: Correction temperature from the JOB initial temperature correction number of sheets to JOB end
Table 3:
NO.
Temperature (°C) -20 -15 -10 -5
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
43
12
Standby mode fusing fan rotation setting
When this simulation is executed, the currently set code number is displayed.
Select a mode to be changed with the arrow keys and enter a set value with numeric keys.
Enter the mode number to be selected with numeric keys and press [OK] key or [START] key. The set value
is saved in the EEPROM.
Sim43-12 FAN SPEED
1:LOW
2:HIGH
[ 0-1]
Setting mode
LOW
Setting in normal temperature adjustment (190°C or below)
HIGH
When the fusing temperature is 190°C or above
Contents
Sim43-4 FUSER TMP 4
5
4:CNTTYPE1
-5
5:CNTTYPE2
3
6:CNTTYPE3
5
Setting item
JOB initial correction temperature *3
JOB latter-half correction temperature *4
JOB initial temperature correction number of sheets
JOB latter-half temperature correction number of sheets 
(Paper size: A3/WLT)
JOB latter-half temperature correction number of sheets 
(Paper size: A4/LT)
JOB latter-half temperature correction number of sheets 
(Paper size: except A3/WLT/A4/LT)
0
1
2
3
4
5
0
5
10
FAN rotation speed
0 : Low speed rotation
0
1 : High speed rotation
1
0
MX-M182 SIMULATIONS 7-30
50
50
25
50
6
7
8
15
20
Remark
Setting range
Default:
-20 - 20 *1
TMPFIRST: 5
-20 - 20 *2
TMPLAST: -5
0 - 255
CNTFIRST: 3
CNTTYPE1: 50
0 - 255
CNTTYPE2: 50
CNTTYPE3: 25
0 - 255
0 - 255
Default:
LOW:0