(3) Developing bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M or
more.
1) Set the digital multi-meter range above 500 Vdc.
2) Put the test rod of the digital multi-meter on the developing bias
voltage output check pin.
3) Turn on the power, execute SIM25-1.
<Specification>
Mode
Developing bias voltage
(4) Grid bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M or
more.
1) Set the digital multi-meter range above 600 Vdc.
2) Put the test rod of the digital multi-meter on the grid bias voltage
output check pin.
3) Turn on the power. 
(The voltage is outputted in the grid bias High output mode during
warming up, and in the grid bias Low output mode when warming up
is completed.)
<Specification>
Mode
Grid bias LOW
Grid bias HIGH
Specification
DC - 400±10V
Specification
DC - 380±8V
DC - 525±10V
MX-M182 ADJUSTMENT 6-2
B. Mechanism section
(1) Image position adjustment
a. OC image lead edge position adjustment (SIM 50-1)
Note:In advance to this adjustment, the sub scanning magnification ratio
adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following
adjustment procedures.
4) Execute SIM 50-01.
Select a desired mode with the arrow keys, enter the adjustment
value with 10-key, and press [OK] key.
When [START] key is pressed, a sheet is printed.
(Mode selection window 1)
Sim50-1 LEAD EDGE
1:TRAY1
50
2:TRAY2
50
3:MFT
50
1/2
[
1- 99]
50
(Copy start window)
Ready to copy.
S
100%
A4
<Adjustment specification>
Adjustment
SIM
Display
mode
text array
OC image lead
SIM
RRC-A
edge position
50-1
Main cassette
TRAY1
print start
position
2nd cassette
TRAY2
print start
position
Multi bypass
MFT
tray print start
position
Lead edge void
DEN-A
5) Set the OC lead edge position set value (RRC-A) to [1]
The OC image scanning start position is shifted inside the document
edge.
6) Set the main cassette lead edge void adjustment value (DEN-A)* to [1]
The lead edge void becomes the minimum.
(Mode selection window 2)
Sim50-1 LEAD EDGE
4:DEN-A
50
5:RRC-A
1
6:DEN-B
50
2/2
[
1- 99]
50
(Copy execution window)
Copies in progress.
S
100%
A4
Set
Spec
Set
value
value
range
R/0.1
Lead edge
1 - 99
void:
1 - 4mm
H/0.1
Image loss:
3mm or
less
B/0.05

Advertisement

loading

This manual is also suitable for:

Mx-m182dMx-m202dMx-m232d