Main
Sub
code
code
42
01
Developing counter clear
Used to clear the developing counter. When this simulation is executed, the confirmation window is
displayed to confirm to clear or not. To clear, press [OK] key or [START] key. Not to clear, press
[INTERRUPT] key or [CA] key to exit the simulation mode.
Sim42-1 COUNTER CLR
DEVELOPER COUNTER
CLEAR
ARE YOU SURE? EXEC
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
43
01
Fusing temperature setting 1
When this simulation is executed, the current set value is displayed.
Every time when [ ] key is pressed, the current display value is increased. For the set value, refer to Table 1
and 2.
Every time when [ ] key is pressed, the current display value is decreased. For the set value, refer to Table
1 and 2.
Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is caved in the
EEPROM.
Sim43-1 FUSER TMP 1
1:READY
2:NORMAL
3:THICK
Window display
1: READY
2: NORMAL
3: THICK
4: MOTORON
5: MOTOROFF
6: WUPEND
*1: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*2: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*3: When the set value is increased by 1, the target temperature is increased by 5°C. (Refer to Table 1.)
*4: When the set value is increased by 1, the target temperature is increased by 10°C. (Refer to Table 2.)
*5: The correction temperature applied to the current target temperature differs depending on the paper
size. For details, refer to SIM43-04.
Table 1:
NO.
Temperature (°C) 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
Table 2:
NO.
Temperature (°C) 80
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Shifts to the sub code input window.
Contents
Sim43-1 FUSER TMP 2
170
4:MOTORON
165
5:MOTOROFF
180
6:WEPEND
170
Setting item
Main thermistor target temperature during standby
Main thermistor target temperature during plain paper 
transmission *5
Main thermistor target temperature during heavy paper 
transmission
Main thermistor temperature when starting main motor 
preliminary rotation
Main motor preliminary rotation end time (sec)
Warm-up compulsory termination time (sec)
0
1
2
3
4
5
0
1
2
3
4
5
90 100 110 120 130 140 150 160
MX-M182 SIMULATIONS 7-28
100
0
23
80
6
7
8
9
10
11
12
6
7
8
Remark
Setting range
Default:
150 - 230 *1
READY: 170
NORMAL: 
150 - 230 *2
150 (18/20cpm machine)
165 (23cpm machine)
150 - 230 *3
THICK: 180
MOTORON: 100
80 - 160 *4
MOTOROFF: 0
0 - 90
WUPEND: 23
0 - 90
13