Download Print this page

Sharp MX-M182 Service Manual page 103

Digital multifunctional system
Hide thumbs Also See for MX-M182:

Advertisement

< Communication result code list >
Result
Final reception signal
code
(Transmitting side)
0
Abnormal signal
1
NSF, DIS
2
CFR
3
FTT
4
MCF
5
PIP, PIN
6
RTN, RTP
7
No signal, DCN
8
PPR
9
10
11
RNR
12
CTR
13
ERR
14
15
16
Abnormal signal
17
NSF, DIS
18
CFR
19
FTT
20
MCF
21
PIP, PIN
22
RTN, RTP
23
No signal, DCN
24
PPR
25
RNR
26
CTR
27
ERR
28
29
V.8 Phase-1
30
V.8 Phase-2
31
V.8 Phase-3
(Note) For result codes 16 - 31, V.34 mode communication.
For 32 or later, refer to the table below.
< Communication result code list >
Result code
Communica-
(Communica-
tion report
tion result)
result column
0 – 31
Refer to the
previous table.
33
Busy
34
Cancel
35
Power OFF
Final reception signal
(Receiving side)
Abnormal signal
(SID), (SUB), NSS, DCS
(PWD), (SEP), NSC, DTC
EOP
EOM
MPS
PRI-Q
DCN
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
RR
CTC
EOR-Q
PPS-PRI-Q
Abnormal signal
SID, SUB, NSS, DCS
PWD, SEP, NSC, DTC
PPS-EOP
PPS-EOM
PPS-MPS, PPS-NULL
PRI-Q
DCN
RR
CTC
EOR-Q
PPS-PRI-Q
V.8 Phase-1
V.8 Phase-2
V.8 Phase-3
Communication interruption
content
Depends on the communication
disconnection position. For 16 or
later, V.34 mode communication.
The calling side cannot connect the
line with the other party.
When a communication
interruption command is delivered
during transmission or reception,
<Send/Receive/Poll/Bulletin>
When the operation is interrupted
by the stop key.
When the power is cur off during
sending or receiving, <Send/
Receive/Poll/Bulletin>
MX-M182 TROUBLE CODE LIST 8-7
Result code
Communica-
(Communica-
tion report
tion result)
result column
38
Reception
memory over
42
Reception
length over
44
Document
error
46
No response
from the other
party
48
OK
49
The other
party has no
polling
function.
50
Polling is not
accepted.
51
Polling allow
number
discrepancy
56
Interface not
accepted
59
The other
party has no
function of F
code bulletin
board.
60
F code polling
is not
accepted.
61
F code bulletin
board number
discrepancy
62
F code bulletin
board
password
discrepancy
63
The other
party has no
function of F
code.
Communication interruption
content
When memory is over during
reception, <Receive/Poll>.
When printing cannot be performed
during reception due to inhibition of
proxy reception, <Receive/Poll>
When the received data length of
one page exceeds the range during
reception, <Receive/Poll>
When a document jam occurs
during direct transmission, <Send>
When the FAX signal from the
other party is not detected within
T1 time, <Send/Poll>
Communication normal end
When the called side has no polling
function in polling reception, <Poll>
When the called side has no
transmission data, <Bulletin>
When DCN is received for DTC in
polling reception, <Poll>
When there is no transmission data
in polling transmission, <Bulletin>
When the allow number does not
coincide in polling transmission,
<Bulletin>
When the system number does not
coincide in polling transmission,
<Bulletin>
1) When DCN is received for NSS
in transmission of the relay
instruction, <Send>
2) When a receiving station
number that is not registered is
instructed in reception of the
relay instruction, <Receive>
3) When F code relay instruction
is received during F code relay
broadcasting, <Receive>
When the other party machine
does not have DIS bit 47 (Selective
polling function) in F code polling
(ringing), <Poll>
When DCN is received for SEP in F
code polling (ringing), <Poll>
When there is no transmission data
for SEP in bulletin board,
<Bulletin>
When the sub address (bulletin
board number (SEP)) does not
coincide in bulletin board,
<Bulletin>
When the pass code (PWD) does
not coincide in bulletin board,
<Bulletin>
When the other party machine
does not have DIS bit 49 (sub
address capacity) in F code
transmission, <Send>. Check that
the other party machine conforms
to F code.

Advertisement

loading

This manual is also suitable for:

Mx-m182dMx-m202dMx-m232d