PCV...-F200-B16-V15
Commissioning
Fieldbus Address
During the first start process, the read head adopts the stored bus address 003 (= default). To
change the fieldbus address of the read head, use code cards for parameterizing the fieldbus
address 001 to 125. These code cards are printed in a separate manual.
You can find the manual for the code cards for configuring the fieldbus address at
www.pepperl-fuchs.com. See chapter 6.2.1.
Baud Rate
Data on the CANopen network can be exchanged at various baud rates of between 10 kBaud
and 500 kBaud. The read head supports the following baud rates:
Baud Rate
10 kBaud
20 kBaud
50 kBaud
125 kBaud
250 kBaud (= default)
500 kBaud
Auto baud rate
The code cards for parameterizing the baud rate from 10 kBaud to 1 MBaud and the auto baud
rate are printed in the Appendix to this manual.
See chapter 8.3.
Code Cards for Controlling Parameterization
The code cards for controlling parameterization are printed in the Appendix to this manual.
See chapter 8.2.
Note!
For external parameterization with code cards, either copy or print the required pages of the
manual. Cut out the required code cards to prevent the read head from mistakenly detecting
another code card on the same page.
However, if you do parameterize the read head using the manual, cover the code cards that you
do not require with a sheet of paper, for example.
Activation of Parameterization Mode
1. Press button 2 on the rear of the read head for longer than 2 seconds.
Yellow LED3 now flashes.
2. Hold the "ENABLE" code in front of the camera system on the read head for final activation
If the "ENABLE" activation code is detected, the green LED2 lights up for 1 s. If the
activation code is not detected, the LED2 lights up red for 2 seconds.
Note!
Time Lock
Start external parameterization of the read head using code cards within 10 minutes of the read
head being switched on. A time lock disables the read head after 10 minutes. The time lock
remains inactive during the parameterization process. The time lock disables the read head if
no parameterization activity takes place for more than 10 minutes.
If you press a button when the time lock is enabled, all LEDs flash and remain lit for 2 seconds
during each flashing cycle.