Intellitouch Ultra Serial Controller (E281-2310); Electrical; Supply Voltage And Current; Interface - Elo TouchSystems IntelliTouch Ultra Product Manual

Table of Contents

Advertisement

   
80 80
 Appendix C - Specif
 Appendix
I I
NTELLI
NTELLI

Electrical

Electrical
C - Specifications
ications
T T
U U
S S
OUCH
OUCH
LTRA
LTRA
Supply Voltage and Current 
Supply Voltage and Current 
+5 Vdc, nominal (+4.75 to +5.25 Vdc).
+5 Vdc, nominal (+4.75 to +5.25 Vdc).
140 mA, typical at +5 Vdc. Average power dissipation is 0.7 W, typical.
140 mA, typical at +5 Vdc. Average power dissipation is 0.7 W, typical.
Supply must be capable of sourcing 200 mA, minimum, and have a rise time of 
Supply must be capable of sourcing 200 mA, minimum, and have a rise time of 
less than 100 ms.
less than 100 ms.
Total noise and ripple requirement must be less than 100 mV (p-p) for frequencies
Total noise and ripple requirement must be less than 100 mV (p-p) for frequencies
below 1 MHz, and less than 5 mV (p-p) for frequencies above 1 MHz.
below 1 MHz, and less than 5 mV (p-p) for frequencies above 1 MHz.
Interface 
Interface 
EIA 232D (Serial RS-232), DCE configuration. 8 Data Bits, 1 Stop Bit, No Parity,
EIA 232D (Serial RS-232), DCE configuration. 8 Data Bits, 1 Stop Bit, No Parity,
Half Duplex. Hardware handshaking: DTR/DSR, RTS/CTS.
Half Duplex. Hardware handshaking: DTR/DSR, RTS/CTS.
Acknowledgments for command set and query.
Acknowledgments for command set and query.
Baud Rate 
Baud Rate 
9600 only.
9600 only.
Operating Modes 
Operating Modes 
Binary in SmartSet or E281A-4002 protocols, jumper selectable.
Binary in SmartSet or E281A-4002 protocols, jumper selectable.
Initial/Stream/Untouch/Z-axis Enable Modes.
Initial/Stream/Untouch/Z-axis Enable Modes.
Touch Resolution 
Touch Resolution 
Approximately 4096x4096, size independent, 255 levels of Z (pressure).
Approximately 4096x4096, size independent, 255 levels of Z (pressure).
Conversion Time 
Conversion Time 
Less than 10 ms per coordinate report.
Less than 10 ms per coordinate report.
Reliability 
Reliability 
MTBF greater than 528,000 hours per MIL-HDBK-217-F2 using parts stress
MTBF greater than 528,000 hours per MIL-HDBK-217-F2 using parts stress
calculation method.
calculation method.