Telnet Method)

RedBoot Procedures
Use the following procedure to update the Bootloader or SocketServer with telnet
to the DeviceMaster UP.
1. Verify that you have the .bin file
2. Open a telnet session, type reset, and close the session.
3. Open a new telnet session and enter the DeviceMaster UP IP address.
$ telnet 192.168.250.250
Trying 192.168.250.250...
Connected to 192.168.250.250.
Escape character is '^]'.
4. Enter the webserver password.
Note: Press the Enter key if you have not programmed a password.
Password:
Comtrol DeviceMaster Bootloader Version 1.20
RedBoot(tm) debug environment - built 14:57:53, Jun 21 2004
Platform: Comtrol DeviceMaster (ARM 7TDMI)
Portions Copyright (C) 2000. Red Hat, Inc.
Portions Copyright (C) 2001-2004. Comtrol Corp.
RedBoot>
5. At the Redboot prompt: type dis and press Enter to disable the bootloader.
RedBoot>dis
Loading disabled
6. Verify that the system responds with an Loading disabled message.
7. Load the file from a TFTP server using the following command and press the
Enter key:
load -r -b 0 -h <TFTP-Server_IP_Addr> <Downloaded_File_Name>
Note: The default IP address is: 192.168.250.250.
RedBoot> load -r -b 0 -h 192.168.250.1 1800110.bin
CCCCRaw load done: 139521 bytes read
Address range: 00000000-00022100, Entry point: 00000000.
xyzModem - Cksum mode, 1091(SOH)/0(STX)/0(CAN) packets, 6 retries
RedBoot>
8. When the RedBoot> prompt appears (after approximately one minute if you
are uploading the Bootloader and approximately three minutes if you ware
uploading SocketServer), type go.
RedBoot>go
If uploading Bootloader: In a few seconds the ethernet and PWR LEDs
cycle through a light sequence once and the update is complete.
(Latest Firmware
on Page 43).