Serial Method)
44 - DeviceMaster UP User Guide: 2000451 Rev. C
e. Select the Send button.
The file name in this screen shows the Bootloader.
10. When the RedBoot> prompt appears (after approximately one minute for the
Bootloader and approximately three minutes for SocketServer), type go.
CCCCCCRaw load done: 542721 bytes read
Address range:
xyzModem - CRC mode, 4241(SOH)/0(STX)/0(CAN) packets, 8 tries
RedBoot> go
... Erase from 0x05030000-0x050c0000: .........
... Program from 0x00000000-0x00084801 at 0x05060000: ...
... Erase from 0x050f0000-0x05400000:
... Program from 0x007a0000-0x007b0000 at 0x053f0000: .
Note: In a few seconds, the ethernet and PWR LEDs cycle through a light
sequence once and then upgrade is complete.
11. If you updated SocketServer: type, fis list and press Enter at the RedBoot>
prompt.
RedBoot> fis list
Name
FIS_directory
0x053F0000
default
RedBoot>
Note: You should see file information for a file called default. If you do not see
this file, repeat the process starting with
12. Reset the DeviceMaster UP by typing reset at the RedBoot> prompt.
RedBoot> reset
. . .Resetting
Note: In a few seconds the ethernet and PWR LEDs cycle through a light
sequence once and the update is complete.
13. Start your internet browser and enter the IP address of the DeviceMaster UP
to verify that the new version of SocketServer loads.
00000000-00084800, Entry point: