Hardware Installation
Observe proper ESD techniques when
connecting and disconnecting the
DeviceMaster UP.
a.Connect the screw terminal power
Caution
connector to the wires on the power supply as
displayed below. If you want to provide your
own power supply, see
Port
on Page 32.
If you are using the power supply
(optionally) shipped with the
DeviceMaster UP:
Red is 5-30VDC positive
White is 5-30VDC return
Black is earth ground
b. Use a small flat head screw to lock
the wires into place.
c.
Plug the screw terminal power
connector into the DeviceMaster UP.
Note: Align the plug properly. The
scalloped side of the screw
terminal power connector
should be aligned with the scalloped side of the power jack on the
unit.
d. Connect the power supply to a power source.
e. Go to
Step 5
to verify that the DeviceMaster UP is functioning properly.
5. Verify that the network connection for the DeviceMaster UP is functioning
properly.
LED
The amber Status LED on the device is lit, indicating you
have power and it has completed the boot cycle.
Status
Note: The Status LED flashes while booting and it takes
If the red Link Act LED is lit, it indicates a working Ethernet
Link Act
connection.
If the red Duplex LED is lit, it indicates full-duplex activity.
Duplex
If the red 100 LED is lit, it indicates a working 100 MB
100
Ethernet connection (100 MB network, only).
6. Go to
Configuring the DeviceMaster UP
configure the network settings, and upload the appropriate protocol firmware
on the DeviceMaster UP.
Power Supply for the 1-
Description
approximately 15 seconds for the bootloader to
complete the cycle.
on Page 19 to install PortVision,
DeviceMaster UP User Guide: 2000451 Rev. C - 11
1-Port Installation
Larger Picture,
Screw Terminal Power Connector
-
Earth Gnd
5-30VDC
+
Wire gauge:
AWG 12-22
Page 35
Return
Positive