Establishing a Serial
Connection

RedBoot Procedures

RedBoot Procedures
Use this section as a reference if you want to perform tasks in Redboot. Typcially,
most of these procedures can be performed using PortVision Plus.
You can use a serial connection between Port 1 on the DeviceMaster UP and a
COM port on a PC. If you plan on using the serial method, you will need a null
modem cable and a terminal program installed and configured on the PC.
Note: Use the serial connection method, if the DeviceMaster UP is not on the same
Ethernet network segment as the PC.
You can use a telnet connection, if the DeviceMaster UP is locally accessible by
Ethernet.
Note: Telnet is not recommended in Microsoft environments, unless you are
familiar with Telnet use in your particular operating system.
If necessary, see

Establishing a Serial Connection

Telnet Connection
on Page 40 to disable the bootloader before performing any of
these procedures.
Use the following procedure to set up serial connection with a terminal server
program (for example, HyperTerminal
1. Connect the null-modem cable shipped with your device from an available
COM port on your PC to Port 1 on the DeviceMaster UP.
Note: If you cannot locate the cable shipped with the DeviceMaster UP, see .
2. Configure a terminal server program (such as, HyperTerminal or Minicom) to
the following values:
Bits per second = 57600
Data bits = 8
Parity = None
Stop bits = 1
Flow control = None
3. Reset the DeviceMaster UP.
Note: Depending on the model, disconnect and reconnect the power cable
(external power supply and no power switch) or turn the power switch
on and then off (internal power supply).
4. Immediately type #!DM and press Enter in the
terminal program.
5. At the RedBoot> prompt, type dis, and press
Enter.
Note: If you do not disable the loading feature of
the bootloader within the time-out period (default is fifteen seconds), an
application will be loaded from flash and started. If this happens,
repeat Steps 3 through 5. The #!DM command is the only case-sensitive
command and must be in uppercase.
6. Verify that the system responds with a Loading disabled message.
on Page 39 or
®
or Minicom) and the DeviceMaster UP.
#!DM
RedBoot>dis
Loading disabled
DeviceMaster UP User Guide: 2000451 Rev. C - 39