12.
CameraLink output timing chart
12.1 Horizontal timing
VIDEO
LVAL
12.2 Transmitter LVDS output pulse position measurement
(1) Base Configuration
(a) 24bit
D.OUT 1
CLKX
X3
X2
X1
X0
When using at Base configuration, please be sure to connect CameraLink cable to D.OUT 1. If the cable is connected to
D.OUT 2, machine may break down.
T
22.2ns (45.0000MHz)
CLK
Previous Cycle
R7-1
R6-1
N.U.
B3-1
B2-1
N.U.
G2-1
G1-1
B1
R1-1
R0-1
G0
1512 clk
1280 clk
Active Picture
Next Cycle
B7
B6
G7
FVAL
LVAL
B5
B0
G5
G4
R5
R4
R3
1CLK= 22.2 ns
G6
R7
R6
B4
B3
B2
G3
G2
G1
R2
R1
R0
N.U.: Not used
27