Page 1
3CCD color camera HV-F130SCL Operation Manual Thank you for purchase this fine Hitachi Kokusai Electric CCD camera. Before using the camera, please read this operation manual carefully. There is a possibility that the revised edition is exhibited on web. Please confirm by web shown in an Installation Guide.
Page 2
IMPORTANT SAFETY INSTRUCTIONS 1. Read Instructions All the safety and operating instructions should be read before the product is operated. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Heed Warnings All warnings on the product and the operating instructions should be adhered to. 4.
Page 3
16. Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product. 17.
Page 4
WICHTIGE SICHERHEITS ANWEISUNGEN 1. Alle Anweisungen lesen Vor Betrieb des Erzeugnisses sollten alle Sicherheits-und Bedienungsanleitungen gelesen werden. 2. Die Anweisungen aufbewahren Die Sicherheits-und Bedienungsanleitungen sollten fünftigen Bezug aufbewahrt werden. 3. Warnungen beachten Die Warnungen auf dem Erzeugnis und in den Bedienungsanleitungen solten beachtet werden. 4.
Page 5
16. Eindringen von Fremdkörpern und Flüssigkeit Niemals Objekte irgendwelcher Art durch die Öffnungen in das Gerät schieben, da diese unter hoher Spannung stehende Teile berühren oder kurzschließen können, wodurch es zu Feuer oder elektrischem Schlag kommen kann. Niemals Flüssigkeiten irgendwelcher Art auf das Erzeugnis verschütten. 17.
Page 6
MISES EN GARDE IMPORTANTES 1. Lire les instructions Lire toutes les instructions de sécurité et de fonctionnement avant de faire fonctionner l’appareil. 2. Conserver ces instructions Conserver les instructions de sécurité et de fonctionnement á des fins de référence ultérieure. 3.
Page 7
16. Pénétration d’objets et de liquides Ne jamais enfoncer d’objets d’aucune sorte dans les ouvertures de l’appareil car ils pourraient toucher des points de tension dangereuse ou court-circuiter des piéces, ce qui pourrait provoquer un feu ou un choc électrique. Ne jamais renverser de liquide d’aucune sorte sur l’appareil.
Page 8
WARNING Changes or modifications not expressly approved by Hitachi Kokusai Electric Ltd. responsible compliance could void the user’s authority to...
Page 9
This page show the declaration of conformity for CE. That reference number is the KV-0394A, and report number is the V3T-0192/ER-0192. Note : This product using the following equipment satisfied the CE standard. The camera cable by shield type (C-201KSS). Mini-CameraLink cable (C-201SCL).
Page 10
China RoHS The following statement is related to the regulation on “ Measures for the Administration of the control of Pollution by Electronic Information Products “ , known as “ China RoHS “. The table shows contained Hazardous Substances in this camera. 说明书(环境方面:补充资料)...
Page 11
Phenomena inherent to CCD imaging device The following phenomena are inherent to a charge coupled device imaging element and do not indicate malfunction. 1) Smear and blooming Vertical bands are visible when a strong light enters the scene. Adjust the camera aiming direction carefully to avoid strong direct or reflected light.
Page 12
・ Sop using the camera at the approach of electrical storm (thunder audible). Protect the camera from rain if using it outdoors. ・ In event the camera shows any abnormality, switch off the camera and disconnect the power cord. Contract a Hitachi Denshi service representative.
Table of Contents Overview ..................................3 Standard composition ..............................3 Features ..................................3 System example ................................3 Section name and functions ............................4 Camera mounting (Attention Hot!) ........................... 4 Lens ..................................... 4 Connector ..................................5 Functions and operations ............................7 TRIGGER : Setting about external trigger ......................
Overview HV-F130SCL is high precision 3CCD progressive scan color camera, which has single chip digital processing LSI, a C mount prism, 1/3 inch 1.3M pixels square CCD and CameraLink interface. Standard composition Check when unpacking Camera ········································································································ 1 Installation guide ····················································································· 1 Plug for DC IN/SYNC connector (HR10A-10P-12S) ··············...
Section name and functions Camera / Tripod adaptor mounting screw holes CameraLink connectors Use for digital video output and camera control signal Lens mount input/output signal. (C mount) Pilot lamp It lights up when power supply. Camera / Tripod adaptor mounting screw holes DC IN/SYNC connector Use for DC+12V power or external...
Connector 1. CameraLink connector (a) Interrelation between number of DATA bit and number of used conndecor Number of Data bits D.OUT1 D.OUT2 24bit (R: 8bit G: 8bit B: 8bit) O: Use 30bit (R: 10bit G: 10bit B: 10bit) -: Not use 36bit (R: 12bit G: 12bit B: 12bit) (b) Signal connection of DIGITAL OUT connector D.OUT1...
Page 18
Recommended CameraLink Cable Cable length Model name C-101SCL C-201SCL C-301SCL C-501SCL 2. DCIN/SYNC connector PIN NO. Signal PIN NO. Signal GND (+12V) TRIG +12V N.C. N.C. FLASH / VD OUT N.C. N.C. Connector (camera side) : SANWOO SHN-10-12 (RPCB) or equivalent Plug (matching cable plug : HR10A-10P-12S(01) HIROSE or equivalent (Note) Please do not unplug and insert cable (camera cable) with a power supplied to a camera.
Functions and operations Various mode setup and adjustment of HV-F32SCL are performed by the remote control via CameraLink. Operation and adjustment way of function utilized are described below. See "Remote control" (page 14 to 20) and "Command list" (page 21 to 26) about communication method of each command. 9.1 TRIGGER : Setting about external trigger -MODE- : Selection of mode OFF (Factory setting)...
-AES MODE- : selects a control mode of AES (Automatic electronic shutter). OFF (Factory setting) : Not perform AES (using manual setting of OFF/PRESET/VARIABLE). : An electronic shutter is controlled automatically so that the brightness of the output image will be practical level. -AES MIN- : setting to shortest speed limit of an AES.
9.7 KNEE : Setting of KNEE -MODE- : Selection of mode OFF (Factory setting) : Not perform knee. : Knee function provides natural gradation in bright portions. -KNEE POINT- : Adjust knee point 0 (Factory setting) to 32 : Setting value toward 0 side increase start level of knee and 32 side decrease start level of knee.
9.11 MASKING : Setting of 6 vector independent making (255) (primary color R G B and complementary color Ye Cy Mg (255) saturation and hue can be separately varied). A figure is showing the masking effects on the color vector. ===>...
9.12 PAINT BLACK : Setting of paint black (color level of R, G, and B can be separately varied). -MODE- : Selection of mode OFF (Factory setting) : Not use paint black functions. : Use paint black functions. -RED- : Adjust red color level 0 (Factory setting) to 127 : Adjust red color level in 128 steps.
9.17 WHITE SPOT : Setting of white spot correction -MODE - : Selection of mode : Not perform white spot correction. ON (Power On status) : Perform white spot correction. (This status follows a power supply start of a camera, and is setting to ON.) -THRESHOLD R- : Threshold of white spot correction for Red CCD 1 to 99 : Set threshold value for Red CCD by output value from 1% to 99%.
Remote control 1. Comms* specifications ・Control system : Start-stop synchronization system ・Transmission rate : 115200 bps ・Data length : 8 bit ・Star bit : 1 bit ・Stop bit : 1 bit ・Parity : None ・Bit transfer : LSB first *Comms: Communications 2.
Page 27
(1) Transmission from master (normal process) HITACH Transmit data (STX-ETX.SUM) 3CCD ACK code (06H) Slave (HV-F32SCL) Master (Machine) ① Master sends data to slave. ② Slave acknowledges receipt of data by again returning ACK to master and end the handshake. (2)...
Page 28
(3) Processing at the time of SUM value error occurred Illegal command SUM value (STX-ETX.??) HITACH NACK code (15H) 3CCD Slave (HV-F32SCL) Master (Machine) ① Transmitted to the slave the command of illegal SUM value from the master. ② If the SUM value is illegal received command, the slave discards the contents of the received, send "NAK"...
Page 29
(5) Data frame error (Master transmission) Send data (ASCII code) HITACH 3 second elapse Send data (ASCII code) 3CCD 3 second Slave elapse (HV-F32SCL) Send data (ASCII code) Master (Machine) 3 second elapse Send data (ASCII code) ① Master sends data. ②...
Page 30
(6) Transmission frame error (Master receive) Read command (ASCII code) HITACH ACK code (06H) 3CCD Read data (ASCII code) Slave 3 second (HV-F32SCL) elapse Read data (ASCII code) Master (Machine) 3 second elapse Read data (ASCII code) 3 second elapse Read data (ASCII code) ①...
Page 31
4. Comms command Text data format (1) Send data and read command (master to slave) (a) Command data are converted into ASCII code and transmitted. (b) Comms byte quantity is 18. (c) Comms data format (transmission sequence). S T X Text data E T X S U M...
Page 32
(2) Read (receive) data (slave to master) (a) Command data are converted into ASCII code and transmitted. (b) Comms byte quantity is 10. (c) Comms data format (transmission sequence) S T X Text data E T X S U M 1 byte 2 byte 1 byte...
Command list 11.1 Send data (setting command, Note: 1 to 7 and SUM need to be transformed into ASCII code) Item AREA RELATIVE STATUS ID NO. DATA ADDRESS [02] [03] MODE FIXED [02] [03] 1TRIG [02] [03] TRIGGER POSITIVE [02] [03] POLARITY NEGATIVE...
Page 34
Item AREA RELATIVE STATUS ID NO. DATA ADDRESS [02] [03] MODE [02] [03] MIN (0) [02] (*2) [03] (*2) TABLE RED[n] MAX (255) [02] (*2) [03] (*2) MIN (0) [02] (*2) [03] (*2) TABLE GREEN[n] MAX (255) [02] (*2) [03] (*2) MIN (0) [02]...
Page 35
Item AREA RELATIVE STATUS ID NO. DATA ADDRESS [02] [03] MODE [02] [03] MIN (0) [02] [03] MAX (127) [02] [03] PAINT BLACK MIN (0) [02] [03] GREEN MAX (127) [02] [03] MIN (0) [02] [03] BLUE MAX (127) [02] [03] [02] [03]...
Page 36
Item AREA RELATIVE STATUS ID NO. DATA ADDRESS PRESET [02] [03] FILE 1 [02] [03] LOAD FILE 2 [02] [03] FILE 3 [02] [03] MEMORY FILE 4 [02] [03] FILE 1 [02] [03] FILE 2 [02] [03] SAVE (*3,4) FILE 3 [02] [03] FILE 4...
11.2 Read-out command (Note: 1 to 7 and SUM need to be transformed into ASCII code) Item AREA RELATIVE STATUS ID NO. DATA ADDRESS MODE [02] [03] TRIGGER POLARITY [02] [03] SOURCE [02] [03] PRESET [02] [03] VARIABLE VALUE (2Byte) [02] [03] SHUTTER...
Page 38
MODE [02] [03] [02] [03] PAINT BLACK GREEN [02] [03] BLUE [02] [03] MODE [02] [03] WHITE SHADING ADJUST [02] [03] [02] [03] DATA BIT [02] [03] SIGNAL [02] [03] OUTPUT POLARITY [02] [03] MODE [02] [03] RED THRESHOLD [02] [03] GREEN THRESHOLD [02]...
Trigger operation and timing chart 13.1 Normal mode (MODE:OFF) Shutter time Data output ① FVAL ② ③ (10pin-OUT) 1 H = 33.6μs 1.1 Shutter time ≦ ① PartialScanMode OFF PartialScanMode ON (Note 14.1.1) BinningVertical BinningVertical BinningVertical OFF BinningVertical ON (2+⌈(12+OFFSET)/9⌉) (2+⌈(8+OFFSET)/9⌉) +9+HEIGHT +9+⌈HEIGHT/2⌉...
Page 43
The following graph is the relationship of the partial scan and "capture width", "frame rate". Equation below is the formula for the "total number of lines by capture width (the decimal point is truncated)" and the "frame rate". (1) Equation of total number of line for partial scan mode The total number of line = 12+⌈(12+OFFSET)/9⌉+HEIGHT+⌈(967-HEIGHT-OFFSET)/9⌉...
13.2 Fixed shutter mode When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start. The exposure time is set by the camera electronic shutter speed. The video output is obtained immediately after the end of fixed exposure. More than ①...
13.3 ONE trigger mode When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start. At the trigger signal falling edge, the video data are transmitted. More than ① High Trigger input(POSI) More than 10μs Shutter time Shutter time (Camera setting value)
14. Input / Output signal 1. Input signal The level of the trigger signal input to HV-F130SCL is as follows. (1) Input from CameraLink cable LVDS level. (2) Input from 12-pin connector 5Vp-p ± 0.5V 2. Output signal The level of the VD/FLASH signal output from HV-F130SCL is as follows.
Specifications Specifications of HV-F130SCL are showing. Optical system 1/3-inch F1.9 prism with IR cut filter Imaging device 1/3-inch interline CCD Total pixels 1372 (H) x 986 (V) Effective pixels 1320 (H) x 976 (V) Active pixels 1280 (H) x 960 (V) Pixel pitch 3.75µm (H) x 3.75µm (V)
Page 49
São Paulo, 01419-001, SP –Brazil Phone: +55(11)3541-3244, Fax: +55(11)3541-2425 URL: http://www.hitachi-linear.com.br/ Hitachi Kokusai Electric Turkey Elektronik Ürünleri Sanayi ve Ticaret A.Ş. Hitachi Kokusai Electric Turkey Yayıncılık Sistemleri A.Ş. Office : Istanbul Endustri ve Ticaret Serbest Bolgesi Akif Kopuz Cad. No.3,...
Need help?
Do you have a question about the HV-F130SCL and is the answer not in the manual?
Questions and answers