13.
Trigger operation and timing chart
13.1 Normal mode (MODE:OFF)
Shutter time
Data output
FVAL
VD
(10pin-OUT)
1.1 Shutter time ≦ ①
PartialScanMode OFF
BinningVertical
OFF
①
990H
②
960H
③
32.2H
1.2 Shutter time > The value of ① indicated in the above table for each condition
PartialScanMode OFF
BinningVertical
OFF
①
Shutter time
②
960H
③
32.2H
(Note 14.1.1) ⌈ ⌉ is Ceiling function.
③
3H
BinningVertical
BinningVertical OFF
ON
(2+⌈(12+OFFSET)/9⌉)
503H
480H
23.2H
(2+⌈(12+OFFSET)/9⌉) H
BinningVertical
BinningVertical OFF
ON
Shutter time
480H
23.2H
(2+⌈(12+OFFSET)/9⌉) H
①
②
PartialScanMode ON (Note 14.1.1)
+9+HEIGHT
+⌈(967-OFFSET
-HEIGHT)/9⌉+1) H
(9+HEIGHT) H
PartialScanMode ON (Note 14.1.1)
Shutter time
(9+HEIGHT) H
1 H = 33.6μs
BinningVertical ON
(2+⌈(8+OFFSET)/9⌉)
+9+⌈HEIGHT/2⌉
+⌈(962-OFFSET
-HEIGHT)/9⌉+1) H
(9+⌈(HEIGHT/2)⌉) H
(2+⌈(8+OFFSET)/9⌉) H
BinningVertical ON
Shutter time
(9+⌈(HEIGHT/2)⌉) H
(2+⌈(8+OFFSET)/9⌉) H