Trigger Operation And Timing Chart - Hitachi KP-FD140GV Operation Manual

Hide thumbs Also See for KP-FD140GV:
Table of Contents

Advertisement

Trigger operation and timing chart

1. Normal mode
Shutter time
Strobe output
(High active)
Data output
VD output
(Low active)
KP-FD140GV/F140GV
(*1) 0.1 to 8190.1us : Approx.2.0us/step
(*2) 2.0 to 8190.0us : Approx.2.0us/step
(*3)
Shutter time
(Camera setting value)
Strobe delay (*1)
Strobe width1 (*2)
Strobe width2 (*3)
KP-FD83GV/F83GV
0.1 to 13104.1us : Approx.3.2us/step 0.1 to 13104.1us : Approx. 1.6s/step
3.2 to 13104.0us : Approx.3.2us/step 3.2 to 13104.0us : Approx. 1.6s/step
Shutter Time – Strobe delay (when duration time is set to 0)
KP-FD33GV/F33GV
25