Configure The Logic Analysis System - Agilent Technologies 16900 Series Service Manual

Logic analyzer modules
Hide thumbs Also See for 16900 Series:
Table of Contents

Advertisement

Chapter 3: Testing Logic Analyzer Performance

Configure the Logic Analysis System

Configure the Logic Analysis System
1 Exit the logic analysis application (from the main menu, choose File→Exit)
and then restart the application. This puts the logic analysis system into its
initial state.
2 Disable all logic analyzers other than the analyzer under test.
a Select the Overview tab at the bottom of the main window.
b Click on each unused logic analyzer and select disable. Only the logic
analyzer to be tested should remain enabled.
3 Set up the bus and signals.
a From the Logic Analysis System main menu, select Setup→My
1691xA→Bus/Signal....
b In the Analyzer Setup window, choose the Threshold button for Pod 1.
40