7.4
TYPE 2 INVERTER SIGNALS
J9
TYPE 2 INVERTER (J2)

8. DISPLAY

At power-on is shown the board version "Htr", after the FW release X.Y.Z and then the status or error code.
The status or error code is always displayed except in programming menu or when is present a blocking error.
On the fi rst 2 digits is shown the status or the error code
: Idle
:
Opening
:
Stopped opening limit switch
:
Stopped opening
:
Closing
:
Stopped closing limit switch
:
Stopped closing
: N/A
On standard working, without errors, the sequence is always 2
->
5
6 when closing
On the third digit and on the dots, additional information are shown:
Display
STATUS
UPS active
STOP signal active
FRAC signal active
Photocell engaged
Control unit
ENCODER
CABLE

8.1 STATUS CODE

:
Stopped due to photocell triggering
:
Opening due to photocell triggering
:
Photocell triggering pause
:
Stopped due to encoder triggering
:
Opening due to encoder triggering
:
Paused due to encoder triggering
:
In opening reached maximum working time
:
In closing reached Maximum working time
- 23 -
CONTROL UNIT
(J9)
B:
Gray
A:
Pink
REV
GND/COM: Green
FWD:
Yellow
FWD
REV:
White
COM
(J6)
GND
+V ENC: Brown
->
3 when opening,
EN
GND ENC
SIG. ENC
+V ENC