Sfps, Xfps, R And Rs Modules, And Power Consumption - Nortel 8600 Installation Manual

Ethernet routing switch
Hide thumbs Also See for 8600:
Table of Contents

Advertisement

66 Ethernet Routing Switch 8600 module fundamentals
For more information about the SFP transceivers and installation
instructions, see Nortel Ethernet Routing Switch 8600 Installation — SFP,
XFP, GBIC, and OADM Hardware Components, NN46205-320.
Nortel qualified the XFP transceivers listed in the following table for use in
Ethernet Routing Switch 8600 interface modules. Only XFP transceivers
qualified by Nortel are supported for use in Ethernet Routing Switch 8600
modules. XFP transceivers not qualified by Nortel can operate within the
module, but are not tested for power draw, electromagnetic interference, or
interoperability.
Nortel has qualified the XFPs listed in the following table.
Table 24
Nortel-qualified XFPs
XFP order number
AA1403005-E5
AA1403001-E5
AA1403003-E5
AA1403006-E5
AA1403007-E6

SFPs, XFPs, R and RS modules, and power consumption

The power specifications for R and RS modules (see
specifications" (page
containing short-range SFPs or XFPs. To calculate the power consumption
of a module with installed medium or long-range optical devices, you can
use the power specifications for the module with short-range devices,
along with the following data:
Copyright © 2008 Nortel Networks
.
XFP type
10GBASE-SR, LC connectors, 850 nm, DDI, up to
300 m
10GBASE--LR/LW, LC connectors, 1310 nm, DDI, up
to 10 km
10GBASE-ER/EW, LC connectors, 1550 nm, DDI, up
to 40 km
10GBASE-ZR/ZW, LC connectors, 1550 nm, DDI, up
to 80 km
10GBASE-LRM, LC connectors, 1310 nm, DDI, up to
220 m
113)) show the power for the module with slots
1000BASE-LX, 1000BASE-BX, 1000BASE-XD CWDM, and
1000BASE-ZD CWDM SFPs
Add 0.15 W for each SFP
1000BASE-EX, 1000BASE-XD DWDM, and 1000BASE-ZD DWDM
SFPs
Add 0.40 W for each SFP
10GBASE-LR, 10GBASE-LRM, and 10GBASE-ER XFPs
Add 1.5 W for each XFP
10GBASE-ZR and DWDM XFPs
Nortel Ethernet Routing Switch 8600
Installation — Modules
NN46205-304 02.02 Standard
16 June 2008