Final Work; Adaptation Of Climatronic J255 Control Unit - Webasto Thermo Top Evo Installation Documentation

Parking water heater audi a4 / a5
Hide thumbs Also See for Thermo Top Evo:
Table of Contents

Advertisement

Audi A4 / A5

Final Work

WARNING!
Reassemble the disassembled components in reverse order. Check all hoses, clamps and all electrical
connections for firm seating. Insulate and tie back all loose lines.
Only use manufacturer-approved coolant. Spray the heater components with anti-corrosion wax
(Tectyl 100K, Order No. 111329).
• Connect the battery
• Fill and bleed the coolant circuit according to the vehicle manufacturer's specifications.
• Set digital timer, teach telestart transmitter
• Make settings on A/C control panel according to the "Operating Instructions for End Cus-
tomer".
• Place the "Switch off parking heater before refueling" signboard in the area of the filler
neck
• For initial start-up and function check, see installation instructions

Adaptation of Climatronic J255 Control Unit

in "Guided functions" mode with VAS 5051/52
Function:
• 08 Heating / Air Conditioning
• 10 Adaptation
Set channel 17 - value from " 0 " to " 1 "
Save