Audi A4 / A5
Final Work
WARNING!
Reassemble the disassembled components in reverse order. Check all hoses, clamps and all electrical
connections for firm seating. Insulate and tie back all loose lines.
Only use manufacturer-approved coolant. Spray the heater components with anti-corrosion wax
(Tectyl 100K, Order No. 111329).
• Connect the battery
• Fill and bleed the coolant circuit according to the vehicle manufacturer's specifications.
• Set digital timer, teach telestart transmitter
• Make settings on A/C control panel according to the "Operating Instructions for End Cus-
tomer".
• Place the "Switch off parking heater before refueling" signboard in the area of the filler
neck
• For initial start-up and function check, see installation instructions
Adaptation of Climatronic J255 Control Unit
in "Guided functions" mode with VAS 5051/52
Function:
• 08 Heating / Air Conditioning
• 10 Adaptation
Set channel 17 - value from " 0 " to " 1 "
Save
Ident. No.: 1318638A_EN
Status: 24.09.2012
Webasto Thermo & Comfort SE
Postfach 1410
82199 Gilching
Germany
Internet: www.webasto.com
Technical Extranet:
http://dealers.webasto.com
© Webasto Thermo & Comfort SE
30