Final Work
WARNING!
Mount removed parts in reverse order. Check all hoses, clamps and all electrical connections for firm
seating. Insulate and tie back all loose wires.
Only use manufacturer-approved coolant. Spray heater components with anti-corrosion wax (Tectyl
100K, Order No. 111329).
- Connect the battery.
- Fill and bleed the coolant circuit according to the vehicle manufacturer's specifications.
- Adjust digital timer, teach Telestart sender
- Make settings on A/C control panel according to the "Operating Instructions for End Cus-
tomer".
- Place signboard "Switch off parking heater before refuelling" in the area of the filler neck
- See installation instructions for initial startup and function check
1
2
1
2
1316981B_EN
Ford Focus / C-Max / Grand C-Max
1 Underride protection
2 60 mm dia. hole
240
85
64
Mount underride protection of engine 1 . Align
exhaust end section 2 flush on underride pro-
tection 1 . Ensure sufficient distance from
neighbouring components.