The problem
occurred in
system date.The
Low battery (for backup of date and time data) level.The battery needs to be replaced. Please
system battery is
return the old battery to one of our branches or regional offices.
insufficient.
Failed to switch
Is a USB disk connected to the controller?
scene
A USB disk is needed to read scenes after scene group 1.
Failed to switch
scene group or
The cause of the failure to switch or to save when switching may be that the USB disk was
save scene group
removed from the controller.Connect a USB disk to the controller and try again.
on switch.
Failed to clear
Confirm that a USB disk is connected to the controller and try again.
scene group.
Check the following points.
Cannot read
Did you remove the USB disk from the controller after selecting a file (files) on the USB
selected
disk?
file.Confirm
Did you delete the selected file? (For example, did you select a file on the RAM disk,
selected file once
which was then deleted via FTP?)
again.
In addition, the selected file may be corrupt.
Switch off controller, verify the following contents and then restart.
Is cable connected correctly?
The
Does it comply with communication specifications of external devices?
communication
Are external devices functioning normally?
time-out is
If error is not resolved after confirmation, the controller may be damaged.Please contact one
occurred.
of our branches or regional offices.
Reference:
Reference:
Error input range.
Please input
Please verify range for setting and perform setting again.
correctly.
File name
Please confirm that characters such as \ / , : ; * ? " < > | & . SPC (space) are not included in the
contains invalid
filename.
character.
Check the following points.
Failed to save
Is the memory of the save destination sufficient?
file.Please check.
For cases where the save destination is the USB disk, is the USB disk connected to the
controller? Or, the controller may not have detected the USB disk.
Fan/voltage error. Switch off controller, and verify if fan is affected.If error information is still shown after restart,
the controller may be damaged. Please contact one of our branches or regional offices.
A camera outside
the guarantee is
A camera not covered by the guarantee is connected to the controller currently being used.
connected.
Destination folder
Check the following points.
is not
Have you deleted the destination folder?
found.Please
For cases where the save destination is the USB disk, is the USB disk connected to the
check.
controller? Or, has the USB disk been detected?
For searching, classification and flexible searching
Cannot perform
Use high-contrast images for model registration.
model
For fine matching
registration.
For fine matching, 2 pixels at the edges of the image cannot be registered with the model.