Alarm Detections; Operator Panel; Figure 3.3.1 Operator Panel; Table 3.2.2 Indications Of Alarms - Fujitsu M2361A Customer Engineering Manual

Mini-disk drive
Table of Contents

Advertisement

3.2.5
Alarm detections
The causes of various alarms and what they indicate when they occur are listed in
Table 3.2.2.
Table 3.2.2
Indications of alarms
Indication
Alarm
Cause
Main Line Sw.
Power AIm LED
Blower AIm LED
Over current of AC
Break
-
-
input
Over current/voltage
-
Light
-
Power
of DC output
Alarm
Over temperature of the
-
Light
-
DC power supply unit
Stopping of fan on the
-
Light
-
DC power supply unit
Blower
Stopping of line blower
-
-
Light
Alarm
3.3
Operator Panel
Switches and indicators on the operator panel are shown in Figure 3.3.1.
On
On
Fault
Start
EJJ~
Protect
Start
Power on
Ready
Figure 3.3.1
Operator panel
(1)
Start (Switch)
If the Spindle Remote/Local switch on the CE panel behind the front panel
is set to Local, it enables rotation of the spindle motor.
When the DC
motor comes up-to-speed, the heads start Initial Seek operation and stop
on cylinder zero.
Approximately 40 seconds later the Ready LED lights.
The spindle motor stops rotating approximately 15 seconds after the switch
is set to the Off position.
When the Remote/Local switch is set to Remote, the spindle motor starts
and stops rotating in accordance with the Spindle Sequence Pick/Hold
commands issued from the controller if the Start switch is On.
B03P-4825-0002A ... OIA