Hour meter mounting
Install the hour meter in the connector
(TMI)
on the back panel.
(See Figure 2.6.3)
Note:
1. The arrow of the hour meter must be the same direction as that on the
connector
(TMI).
2. If the indicator is fully changed to red, pullout the hour meter and
change the direction.
Figure 2.6.3
Back panel PCB
2.6.4
Line terminator mounting
CD
Install the line terminator PCB in the "out" connector for A-cable of the
interface PCB.
(See Figure 2.6.1)
CD
Connect the GND cable of the line terminator PCB to the GND terminal on
the interface PCB using the screw "B".
2.7
Cabling
2.7. 1
Cables
All cables are connected in the rear of the drive unit.
(1)
Cable list
Cables consist of;
a.
Interface cables
---r-
A-cable
--r
for Data Transfer
LB-cable
~
b.
AC Power cable--- Power Cable
B
for 200-240V
2 - 10
or Power Cable C }
or Power Cable DE
for 100-120V
or Power Cable
B03P-482S-0002A ••• Ol