LEVELER SCREW
ASSEMBLY
4 X 30
FOLD CYLINDER
1-1/2-6 HEX
LOCK NUT
LEVELER
TUBE
LEVEL INDICATOR
GAUGE
LEVEL
INDICATOR ROD
6230hydlevel 1
4-10 HYDRAULIC LEVELER GAUGE ADJUSTMENT
If a unit is equipped with an optional hydraulic
leveler, and the unit is level in the field, but the ref-
erence gauge is not in the middle of the adjust-
ment range, the gauge may be adjusted.
4-10.1
Lower the disc to the ground to remove
the load on the leveler assembly.
4-10.2
Remove the level indicator rod from the
leveler tube (See Figure 4-11).
4-10.3
Loosen the 1-1/2-6 hex lock nut at the
rear of the leveler tube (an adjustment
wrench is provided for this).
Figure 4-11 Hydraulic Leveler Gauge Adjustment
4-10.4
Screw the leveler tube in or out. Insert
the indicator rod to check if the reference
gauge is centered. Adjust as required to cen-
ter the reference gauge. Make sure the hole
for the indicator rod is horizontal and tighten
the locking nut on the leveler screw.
4-10.5
Install the level indicator rod in the lev-
eler tube and level indicator gauge.
4-11