Tank Agitator Installation; Initial Plumbing And Point Of Injection; Best Practices - Raven SideKick Pro Installation & Operation Manual

Icd 1-40 oz./min. and 5-200 oz./min.
Table of Contents

Advertisement

CHAPTER 4

TANK AGITATOR INSTALLATION

NOTE:
Over agitation may add air to the tank or cause the chemical to break down and cause inaccurate
application.
The following agitators are available for use with the Sidekick Pro™ ICD system. Refer to the installation guide
shipped with the agitator for installation instructions.
Available Tank Agitators
TABLE 1.
Agitator
Type
Mix-All
Mix-All
Raven
Raven

INITIAL PLUMBING AND POINT OF INJECTION

BEST PRACTICES

• The Raven Sidekick Pro™ ICD injection system pumps chemical into the main carrier line at the point of
injection. This point must be on the pressure side of the carrier product pump and should be as close to the
boom section valves as possible.
• It is not necessary for injected products or chemicals to be measured by the flow meter. Depending upon the
type of applications or chemical mixtures with which the injection system will normally be used, it may be more
desirable to place the injection point after the flow meter. This configuration may help to extend the service life
of the flow meter and components by minimizing exposure to corrosive chemicals.
• Use check valves in both the carrier and injection lines to prevent back flow and contamination of carrier and
chemical reservoirs.
• Install an in-line mixer after the point of injection to ensure even mixing of the injected product.
A mixer assembly with a carrier check valve included is recommended.
Additional tee fittings may be required for each injected chemical.
A separate injection check valve is required for each injected chemical.
FIGURE 2. Point of Injection Detail
From Carrier
Product Tank
16
SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual
Blade Size
3"
4"
3"
Raven 24 Gallon Tanks
3"
Raven 50 Gallon Tanks
From
Injection
Module
Point of
Injection
Carrier
Check Valve
Tank
Non-Raven Tanks
Non-Raven Tanks
Injection
Point Check
Valve
In-Line Mixer
Part Number
910-0000-331
910-0000-341
117-0159-544
117-0171-655
To Boom Valve
Manifold

Advertisement