Advertisement

4. Return to the control console and select the injection product to calibrate.
Sidekick Pro
ICD Menu
5. Select Diagnostics.
6. Select Test.
7. Select Catch Test from the drop-down.
8. Enter the volume of injected chemical to use for the catch test.
9. Select the Next button on the screen. The injection pump will run until the entered catch test volume has been
dispensed.
NOTE:
Select the Red X to stop the catch test at any time.
10. Check the amount caught in the catch vessel after the catch test is complete. The caught volume should be
within ±3% of the desired amount. If the caught volume is off by more than ±3%, adjust the Flow Correction
percentage value. Increase the Flow Correction% by the approximate error percentage to pump more fluid.
Decrease the Flow Correction% to pump less fluid.
NOTE:
If the console displays an error message during the catch test, verify the conditions listed in step 2
exist. If the problem persists, refer to the Chapter 7, Troubleshooting, for assistance.

DEMONSTRATION MODE

Use Demonstration Mode to simulate pressure with a specified value and to stimulate flow. To operate the
Sidekick Pro™ ICD in demonstration mode:
1. Select the Diagnostics icon.
2. Select Test.
3. Select Demonstration Mode.
Calibration and Operation: Tests
Diagnostics
Test
CALIBRATION AND OPERATION
Next
41