Photocell Test - Silca Quattrocode Operating Manual

Table of Contents

Advertisement

Operating manual - English
7.2

Photocell test

In addition to the sensors already described there are two photocells for micrometric detection of
the X and Y carriage end of runs.
Test 201: X axis photocell (lateral carriage)
-
When the carriage is moved very slowly by hand to the right then to the left, the display will
show:
If the transition from ON to OFF does not occur, contact Silca After-Sales Service.
Test 202: Y axis photocell (front carriage)
-
When the carriage is moved very slowly by hand towards the machine then back towards the
operator, the display will show:
If the transition from ON to OFF does not occur, contact Silca After-Sales Service.
Test 203: B axis photocell (supplementary - optional)
The B axis is provided for the future use of additional devices for the Quattrocode, such as special
clamps which will be controlled through the B connection on the right-hand side of the machine (in
the standard version of the Quattrocode this function is not activated).
30
<TEST 201 ON>
<TEST 201 OFF>
<TEST 202 ON>
<TEST 202 OFF>
Copyright Silca 1999