2 - Machine Operation
2.1 - Powering the ECO PRO
Included 50'
extension cord
The Orbital Floor Machine requires a 20 amp, 115V power
outlet to operate.
Plug the female end of the 50' twist-lock extension cord
into the Orbital Floor Machine's pigtail power cord and
twist clockwise to lock. Plug the male end of the extension
cord into a wall outlet.
♦
2.2 - Connecting the Spray Gun
The coiled hose attached to the spray gun features a
female quick disconnect fitting which connects to the male
quick disconnect fitting to the left of the pump.
2.3 - Pad Drivers, Pads, and Brushes
Pad Driver
The pad driver comes pre-installed on Mytee's Orbital
Floor Machines. To remove the pad driver, undo the four
screws on the bottom of the pad driver.
Applying Cleaning Pad
To apply a cleaning pad, just lower the machine with pad
driver onto a pad. Make sure the pad is as centered as
possible on the pad driver with no driver bristles exposed
to carpet.
Tile & Grout Brush
To apply the optional Tile & Grout Brush, remove the
pre-installed pad driver via the four screws holding it in
place. Screw the Tile & Grout Brush directly into the bear-
ing just like the pad driver was.
2.4 - Filling the Shampoo Tank
♦
Faucet Fill
The shampoo tank can be filled from a standard faucet.
Simply lift the Faucet Fill hose out of the tank and press it
against the faucet. Turn on the faucet to allow water to flow
10
♦
IMPORTANT: When filling with
a bucket, tilt the handle back in
order to avoid spilling water on
the motor.