2 - Machine Operation

2.1 - Powering the Breeze™

Connect power cords by lining up the female end of the cord with the male prongs in the
socket on the machine. Twist clockwise to lock the cord in place.
Each power cord on the Breeze™ requires a grounded 20 amp outlet. For dual cord
machines, plug each cord into its own 20 amp circuit. The dual circuit indicator light and
tone will activate when this is achieved.

2.2 - Connecting Hoses

Use the included Cuff-Lynx™ hose connectors to connect 1.5" or 2" vacuum hose to the hose connection at the top of
the recovery tank. Connect the solution hose via the quick connect fitting on the front of the unit's base (refer to pages
7-8 for connection locations).

2.3 - Filling the Solution Tank

The Breeze™ solution tank can be filled up from a bucket via the opening under the solution tank lid, or via the auto-fill
for BZ-AUTO units (see section 2.6).
2.4 - Switching On the Breeze™ Components
Units Without Heater (BZ-102LX, BZ-102LX-AUTO, BZ-105LX, BZ-105LX-AUTO)
After a cleaning tool is connected and the solution tank is filled, switch on the vacuums and the pump in any order.
Unit With Heater (BZ-102LXH)
The BZ-102LXH unit features a 3-position switch to switch between Vacuum 2 or the 1,600 watt heater. In order to
avoid vapor locking the unit, the components should be switched on by following the procedure below after a cleaning
tool is connected:
1. Turn pump switch on. Pull the lever on the cleaning tool to release air in the line. Hold lever until a steady flow of
water comes out of the wand.
2. Once pump is primed and there is pressure in the solution line, turn on heater switch and wait a few minutes for
water to heat up.
3. Once water is heated, turn on vacuum and begin cleaning.

2.5 - Chemical Injection (BZ-AUTO Units Only)

Fill the included 5 qt. bottle with chemical concentrate of your choice. With a cleaning tool connected, switch on the
pump and pull the trigger on your tool to keep water flowing. Turn the chemical injection knob counter-clockwise to
open the valve. This allows chemical to siphon into the line. Turn the knob until you see the bubble reach the desired
gallons per hour of chemical. Follow chemical manufacturer's instructions for correct ratio.
IMPORTANT: If chemical injection will not be used, make sure the chemical injector is closed by turning the knob
all the way clockwise.

2.6 - Auto-Fill and Pump-Out (BZ-AUTO Units Only)

Auto-fill: Connect standard garden hose from water source to the auto-fill connection on the front of the unit. Turn on
the water source and let the tank begin to fill. It will shut off when the water level reaches the float switch in the solution
tank.
Pump-out: Connect a second standard garden hose to the pump-out connection and lay the other end of the hose in a