HP-100/HP-60 This manual is furnished with each new model. It provides necessary operation and maintenance MACHINE DATA instructions and an illustrated parts list. Read this manual completely and understand the machine before operating or servicing it. Use the illustrated Parts List to order parts. Before...
HP-100/HP-60 SAFETY PRECAUTIONS 4. Before leaving or servicing machine: ♦ ♦ ♦ ♦ Turn off machine. ♦ ♦ ♦ ♦ Unplug cord from wall outlet. This machine is intended for commercial use. It is 5. When servicing machine: designed to clean carpet and upholstery in an indoor ♦...
HP-100/HP-60 SAFETY LABELS The safety labels appear on the machine in the locations indicated. Replace labels if WARNING: Flammable materials can they become damaged or cannot be read. cause an explosion or fire. Do not use flammable materials in tank(s). Flammable materials or reactive metals can cause explosion or fire.
HP-100/HP-60 PRE-OPERATION NOTE: Make sure the quick disconnects snap together firmly. As Vacuum carpet and upholstery and remove you do this, always inspect hoses for other debris. cracks or fraying. Do not use if hoses Perform MACHINE SETUP procedures. are damaged.
HP-100/HP-60 7. Plug machine’s cord into a grounded wall outlet. 4. Turn on vacuum power FOR SAFETY: Do not operate machine unless cord is properly grounded. 5. Begin cleaning FOR SAFETY: Do not operate machine with the use of an extension cord.
HP-100/HP-60 DAILY MAINTENANCE DRAINING RECOVERY TANK FOR SAFETY: When servicing machine, 1. Empty and rinse out solution tank thoroughly. unplug cord from wall outlet. 2. Wipe off power cord and check for damage, replace if necessary. Coil cord neatly after use.
HP-100/HP-60 STORING MACHINE Before storing machine, be certain to completely drain and rinse tanks of all water and solution. Drain and dry the vacuum hose as well, using the drain hose provided Store machine in a dry area in the upright position.
Page 9
HP-100/HP-60 PROBLEM: Brass check valve is stuck. SOLUTION: Replace with new check valve. SYMPTOM: VACUUM MOTOR IS NOT WORKING PROPERLY: PROBLEM: Hose not connected tightly to upholstery tool or machine. SOLUTION: Connect hose tightly. PROBLEM: Drain valve is not shut completely.
Page 10
HP-100/HP-60 DESCRIPTION WHERE USED PART NUMBER Vacuum motor HP100 C302 3 stage 115v HP60 Quick connect HP100 Female ¼” HP60 B102 Quick connect HP100 B101 Male ¼” HP60 Element heater HP100 E571 600 watt HP60 HP100 Switch, 2 position HP60...
Page 12
HP-100/HP-60 Limited Warranty It is the constant endeavor of Mytee Products, Inc. to give our customers the highest quality products obtainable. Mytee Products, Inc. warrants each new product purchased from any authorized Mytee Products, Inc. distributor/service center to be free from defects in both...