2 - Machine Operation
2.1 - Powering the Speedster®
Each power cord on the
Speedster® requires a
grounded 20 amp outlet.
For dual cord machines,
plug each cord into its own
20 amp circuit. The dual
circuit indicator light and
tone will activate when this
♦
is achieved.
Components on each cord.
Machine
Primary Cord always marked with yellow tag.
1000DX-200 Primary Cord:
1001DX-200
Primary Cord:
Secondary Cord: Vacuum 2
1003DX
Primary Cord:
Secondary Cord: Vacuum 2
1005LX
Primary Cord:
Secondary Cord: Vacuum 2
2.2 - Connecting Vacuum & Solution Hoses
IMPORTANT: Do not pull on hoses in
order to move the unit. Only use the
appropriate handles.
Use the included Cuff-Lynx™ hose connectors to
connect 1.5" or 2" vacuum hose to the Speedster®.
Connect the solution hose via the quick connect fitting
on the front of the Speedster®.
Vacuums 1 & 2
Pump
Vacuum 1
1,000 Watt Heater
Pump
1,000 Watt Heater
Vacuum 1
600 Watt Heater
Pump
1,000 Watt Heater
Vacuum 1
Pump
♦
2.3 - Filling the Solution Tank
The Speedster® solution tank can be filled up via the
faucet fill hose or from a bucket via the opening under the
solution tank lid.
IMPORTANT: Do not use acid (acid rinse) or high
alkaline chemicals like sodium hydroxide in the
1003DX or 1005LX machines. This will cause damage
to the pump and void the warranty.
IMPORTANT: Use only low foam or non foaming
detergent or shampoo. Damage due to excessive foam
will void warranty.
♦
2.4 - Switching on the Speedster®
Units Without Heater (1000DX-200, 1005LX)
After a cleaning tool is connected and the solution tank is
filled, switch on the vacuums and the pump in any order.
Units With Heater (1001DX-200, 1003DX)
In order to avoid vapor locking the unit, the components
should be switched on by following the procedure below
after a cleaning tool is connected:
1
1. Turn pump switch on. Pull the lever on the cleaning tool
to release air in the line. Hold lever until a steady flow of
water comes out of the wand.
10