2 - Machine Operation

2.1 - Powering the Speedster®
Each power cord on the
Speedster® requires a
grounded 20 amp outlet.
For dual cord machines,
plug each cord into its own
20 amp circuit. The dual
circuit indicator light and
tone will activate when this
is achieved.
Components on each cord.
Machine
Primary Cord always marked with yellow tag.
1000DX-200 Primary Cord:
1001DX-200
Primary Cord:
Secondary Cord: Vacuum 2
1003DX
Primary Cord:
Secondary Cord: Vacuum 2
1005LX
Primary Cord:
Secondary Cord: Vacuum 2
2.2 - Connecting Vacuum & Solution Hoses
IMPORTANT: Do not pull on hoses in
order to move the unit. Only use the
appropriate handles.
Use the included Cuff-Lynx™ hose connectors to
connect 1.5" or 2" vacuum hose to the Speedster®.
Connect the solution hose via the quick connect fitting
on the front of the Speedster®.
Vacuums 1 & 2
Pump
Vacuum 1
1,000 Watt Heater
Pump
1,000 Watt Heater
Vacuum 1
600 Watt Heater
Pump
1,000 Watt Heater
Vacuum 1
Pump

2.3 - Filling the Solution Tank

The Speedster® solution tank can be filled up via the
faucet fill hose or from a bucket via the opening under the
solution tank lid.
IMPORTANT: Do not use acid (acid rinse) or high
alkaline chemicals like sodium hydroxide in the
1003DX or 1005LX machines. This will cause damage
to the pump and void the warranty.
IMPORTANT: Use only low foam or non foaming
detergent or shampoo. Damage due to excessive foam
will void warranty.
2.4 - Switching on the Speedster®
Units Without Heater (1000DX-200, 1005LX)
After a cleaning tool is connected and the solution tank is
filled, switch on the vacuums and the pump in any order.
Units With Heater (1001DX-200, 1003DX)
In order to avoid vapor locking the unit, the components
should be switched on by following the procedure below
after a cleaning tool is connected:
1
1. Turn pump switch on. Pull the lever on the cleaning tool
to release air in the line. Hold lever until a steady flow of
water comes out of the wand.