2 - MACHINE OPERATION
Before Operating
Take the included mesh
filter bag and place it over
the pump-out filter inside
the black recovery tank.
This filter helps prevent any
solid debris from damaging
the pump-out.
♦
2.1 - Powering the Speedster® LTD
Each power cord on the
Speedster® LTD requires
a grounded 20 amp outlet.
For dual cord machines,
plug each cord into its own
20 amp circuit. The dual
circuit indicator light and
tone will activate when this
is achieved.
♦
Components on each cord.
Machine
Primary Cord always marked with yellow tag.
LTD3
Primary Cord:
Secondary Cord: Vacuum 2
LTD5
Primary Cord:
Secondary Cord: Vacuum 2
LTD12
Primary Cord:
Secondary Cord: Vacuum 2
2.2 - Connecting Vacuum & Solution Hoses
Use the included Cuff-Lynx™ hose connectors to connect
1.5" or 2" vacuum hose to the Speedster® LTD. Connect
the solution hose via the quick connect fitting on the front
of the Speedster® LTD.
2.3 - Filling the Solution Tank
The Speedster® LTD solution tank can be filled up from
a bucket via the opening under the solution tank lid or via
the auto-fill feature (section 2.5).
Vacuum 1
600 Watt Heater
2.4 - Switching on the Speedster® LTD
Pump
Units Without Heater (LTD5, LTD12)
After a cleaning tool is connected and the solution tank is
filled, switch on the vacuums and the pump in any order.
1,000 Watt Heater
Pump-Out
Units With Heater (LTD3)
Vacuum 1
Pump
Pump-Out
Vacuum 1
Pump
Pump-Out
In order to avoid vapor locking the unit, the components
should be switched on by following the procedure below
after a cleaning tool is connected:
1. Turn pump switch on. Pull the lever on the cleaning
2. Once pump is primed and there is pressure in the
10
♦
3
1
tool to release air in the line. Hold lever until a steady
flow of water comes out of the wand.
solution line, turn on heater switch and wait a few
minutes for water to heat up.
♦
2