SETUP & PROGRAMMING
REPEATER PANEL SETUP & PROGRAMMING
The panel can support up to 8, fully functional repeater panels on the network.
Repeater Comms PCB
To run repeaters, a Comms PCB (TPCA05) must be fitted to the control panel. The repeater panels are
supplied with the comms board fitted.
The Comms PCB fits into the control panel on top of the main circuit board where the ribbon cable from
the display board is normally plugged.
To fit the Comms PCB, power down the panel, un-plug the display board ribbon cable from the main circuit
board and plug the Comms PCB into the socket instead.
A socket is provided on the top of the Comms PCB to re-connect the display board ribbon cable.
PSU
28V 0V
@ +
-
-
+
Disconnect display board ribbon cable
Once the Comms PCB has been fitted, switch 5 on the 6 way DIL switch located on the main circuit board
should be switched to the ON position.
With this switch in the ON position the panel will automatically recognise &
operate the Comms PCB (TPCA05).
Next, the panel will need to be programmed for the number of repeater panels on the system. See panel
wide settings 2-1-2-3 option 2 (Set Number of Repeater Panels on System).
Addressing
Each repeater panel needs to have a seperate address. The addressing is done using the 4 DIL switches
on each of the Comms PCBs using binary code values, see diagram below.
The address should be set in sequence from 1 - 8, first repeater address 01, next repeater address 02 etc.
The control panel should always be address 00 (all switches off).
ON
ON
ON
1
2
3
4
1
2
3
4
1
ADD 01
ADD 02
ON
ON
ON
1
2
3
4
1
2
3
4
1
ADD 05
ADD 06
Esento Marine 8-12 Installation, Commissioning & Operating Manual
FIRE
FAULT
FR
FLT
CC
PUL
SNDR1 SNDR2
ZONE1 ZONE2 ZONE3 ZONE4
+ -
+ -
+ -
+ - + -
C NC NO
C NC NO
-OP -OP -IP -IP
ON
+ -
1
BATTERY
6 way DIL switch
Network System Note:
ON
2
3
4
1
2
3
4
Repeater panel addresses are parallel to network slave
ADD 03
ADD 04
panel addresses on a network system.
ON
I.e. a repeater and a network slave panel can both have
address 01 on the network.
2
3
4
1
2
3
4
ADD 07
ADD 08
PSU
28V 0V
FIRE
+ -
@ +
-
-
+
C NC NO
COMS A
COMS B
28
SW -ve OUTPUTS
+ - + -
1
2
3
4
V+
ON
1
2
3
4
ADDRESS
2
3
4
5
6
Plug Comms PCB into the socket and
re-connect dispay board ribbon cable to
socket on top of Comms PCB
Approved Document Ref: UI-ESEN12MAR-01 Issue 8.0
46
FAULT
FR
FLT
CC
PUL
SNDR1 SNDR2
ZONE1 ZONE2 ZONE3 ZONE4
+ -
+ -
+ -
+ - + -
+ -
C NC NO
-OP -OP -IP -IP
5
6
ON
+ -
1
2
3
4
5
6
BATTERY
ON
1
2
3
4
5
6
ON = Network/
Repeater mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esento esen-12mar0832-med-1086

Table of Contents