Automatic self-test (when there is an invalid setting)
B-EP2DL-G
MAIN
01JAN2008 V1.0 :A700
BOOT 01JAN2008 V1.0 :2400
SBCS C/G
DBCS JAPANESE V1.0 :0A00
HTML 01JAN2008 V1.0 :AB00
EEPROM
OK
SDRAM
16MB
SENSOR1 00000000,00000000
SENSOR2 [H]+20°C [A]+22°C
[R]4.2V [T]2.5V
PE LV.
[R]1.8V [T]2.5V
M THRE.
[R]1.8V [T]2.5V
BATTERY 16.5V [5]
I/F
USB/IrDA/232C
LOOPBACK
IrDA
OK
RS-232C
BLUETOOTH
-
WIRELESS LAN -
When there is an invalid setting, the slant line pattern is printed.
Conditions to print slant line pattern:
Battery voltage per cell is less than 2.3 V or 4.25V or more.
Head temperature is -25°C or less or 65°C or more.
Ambient temperature is -25°C or less or 65°C or more.
Transmissive sensor input voltage is 0V or 5V.
Reflective sensor input voltage is 0V or 5V.
Transmissive sensor: When the D/A value is 0, the A/D value read again is 3V or more. (*1)
Reflective sensor: When the D/A value is 0, the A/D value read again is 3V or more. (*2)
Loopback test error (except for RS-232C)
(*1): When the transmissive sensor is attached upside down, the A/D value sometimes becomes 3V or more
when the D/A value is set to 0.
(*2): When the reflective sensor is attached upside down, the A/D value sometimes becomes 3V or more when
the D/A value is set to 0.