Forward to Wiegand Output – set a group of Wiegand outputs to which all the
received RFID card IDs will be resent.
Tip
To accelerate card reading, you are recommended to select the card
types used by the user in the module settings.
Bluetooth Module
Module Name – set the module name for logging events from the Bluetooth
module.
Door – set the reader direction (Not specified, Arrival, Departure) for the
Attendance system purposes.
Associated Switch – set the switch to be activated after user authentication via
this module. If you set Door Lock Switch, the authentication rules specified in
Hardware / Door will be used.
Signal Range – set the maximum signal range, i.e. the distance within which the
Bluetooth module can communicate with the mobile phone:
Short – less than 50 cm for most phones
Middle – less than 2 m for most phones
Long – maximum possible range