Sound Signalling – set the sound signalling type for switch activation. Choose
the Short beep or Long beep (during the whole activation).
Synchronise with – set switch synchronisation to enable automatic switch
activation after another switch activation with a predefined delay. Define the
delay in the
Synchronisation Ddelay
parameter.
Synchronisation Delay – set the time interval between synchronised activations
of two switches. The parameter will not be applied unless the Synchronise
function is enabled.
Switch-On Command – set the command to be sent to the external device (WEB
relay, e.g.) upon switch activation. The command is sent via the HTTP (GET
request) and must be as follows:
http://ip_address/path
. E.g.:
http://192.168.1.50
/relay1=on
.
Switch-Off Command – set the command to be sent to the external device
(WEB relay, e.g.) upon switch deactivation. The command is sent via the HTTP
(GET request) and must be as follows:
http://ip_address/path
. E.g.:
http://192.
168.1.50/relay1=off
Username – enter the username for the external device (WEB relay, e.g.)
authentication. The parameter is obligatory only if the external device requires
authentication.
Password – enter the external device (WEB relay, e.g.) authentication password.
The parameter is obligatory only if the external device requires authentication.
2N TELEKOMUNIKACE a.s., www.2n.cz
44/128