Use Factory Firmware

Activation
To start the Use Factory Firmware reset mode and replace firmware:
On the TLSI 201, hold down the recessed Reset button while applying power to the
1.
unit. Hold the button down until the Power LED blinks twice. The TLSI 201 enters
factory firmware mode, and the LED flashes quickly.
Upload new firmware to the unit as desired (see
2.
page 19).
NOTE:
firmware to the latest version. Do not operate the interface firmware version that
results from the reset. This mode temporarily resets the unit to factory default until
power is recycled. If you want to use the factory default firmware, you must upload
that version again (see
Result
The unit continues to run factory-installed firmware until you update the firmware or power
is cycled to the unit, which then reboots with the last loaded version of the firmware. The
TLSI 201 reverts to the factory default firmware. Event scripting does not start if the unit
is powered on in this mode. All user files and settings such as drivers, adjustments, and
IP settings are maintained.
NOTE:
power to the unit.
Purpose and Notes
Use this mode to temporarily boot up the unit with factory installed firmware for a single
power cycle in the event that a firmware update has failed or if incompatibility issues arise
with user-loaded firmware.
User-defined web pages may not work correctly if you are using an earlier firmware version.

Reset All IP Settings

Activation
To reset all IP settings:
Hold down the Reset button for about 6 seconds until the Power LED blinks twice
1.
(once at 3 seconds and again at 6 seconds).
Release and press Reset momentarily (for <1 second) within 1 second. Nothing
2.
happens if the momentary press does not occur within 1 second.
Result
Reset All IP Settings mode:
Sets the IP address back to factory default (192.168.254.251).
Sets the subnet back to factory default (255.255.255.0).
Sets the default gateway address to the factory default (0.0.0.0).
Turns DHCP off.
Purpose and Notes
Reset All IP Settings mode enables you to reset IP settings and port maps to factory
defaults.
After a User Factory Firmware reset is performed, update the
Updating the Firmware
To return the unit to the firmware version that was running prior to the reset, cycle
Updating the Firmware
on
TLSI 201
).
TLSI 201 • Reference Material