Your rising barrier type BL52/BL53 has been designed to operate in any kind of climatic environment,
from -35°C to +50C (thanks to heating resistance), with up to 95% of relative humidity.
2.5.
Emergency operation
The following instructions are to be given to the installation supervisor.
2.5.1.
Opening or closing in case of power failure
--
Insert the emergency crank handle (1:11) into the crank hole (1:10). A safety device automatically
switches off the power supply, thus eliminating any risk of accident in case the power supply
returns.
--
Turn the crank clockwise to open the barrier and counter' clockwise to close the barrier
--
When the arm is in the horizontal or vertical position, keep turning the crank to lock the barrier
mechanically.