4. Remove the 2 bolts and two nuts anchoring the Flue Opening Cover to the back. Carefully remove the Cover from
the of the back of the firebox (Figure 7). Careful - do not damage the gasket.
5. Install the Flue Opening Cover and casket on the top (Figure 8), Ensure the gasket is in place and laying flat against
the stove. Use the removed bolts to secure. Torque the bolts to hand tight then a 1/4 turn at a time until firm.
Figure 7: Flue Conversion Step 4.
6. Locate the flue collar on the back of the unit with the opening pointed up (Figure 9). Ensure the gasket is in place and
laying flat against the stove. Reinstall the collar using the nuts and bolts that were removed from the back (Figure 6).
Install the back cover.
7. Re-install the Top by engaging the two front bolts into the mounting brackets and install the machine screws thru the
back shield into the top. Center the top to the front/side casting then tighten the front bolts and rear screws.
8. Install the Cast Iron Flue Cover to the Air Jacket using the screws provided. It can be adjusted slightly to get the
best fit. (Note the top may need to be adjusted to find the perfrct alignment.)
Figure 10: Flue Conversion Step 8.
5055.7298-A
Figure 9: Flue Conversion Step 6.
Figure 8: Flue Conversion Step 5.
Figure 11: Flue Conversion Final.