8.3.1 To connect the main power supply

ERLA03DAV3 + EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596806-1 – 2019.10
Item
Remote outdoor sensor
Remote indoor sensor
LAN adapter
LAN adapter – System requirements
The requirements posed on the Daikin Altherma system depend on the LAN
adapter application/system layout (app control):
Item
LAN adapter software
Unit control method
1 Open the following (see
1 Top panel
2 Upper front panel
3 Upper switch box cover
2 Connect the main power supply.
Description
See:
Installation manual of the remote outdoor
sensor
Addendum book for optional equipment
Wires: 2×0.75 mm²
[A.2.2.B]=1 (External sensor=Outdoor
sensor)
[A.6.5] Ext amb. sensor offset
[A.6.4] Averaging time
See:
Installation manual of the remote indoor
sensor
Addendum book for optional equipment
Wires: 2×0.75 mm²
[A.2.2.F.5]=2 (External sensor=Room
sensor)
[A.3.2.3] Ext. room sensor offset
See:
Installation manual of the LAN adapter
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²). Must be
sheathed.
Maximum length: 200 m
See
"LAN adapter – System
4
requirements" [
Requirement
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
On the user interface, make sure to set [A.2.1.7]=2
(Unit control method = RT control)
"6.2.4 To open the indoor
8
Electrical installation
|
 93]
4
unit" [
 54]):
1
Installer reference guide