Routing
Possible cables (depending on unit type and installed options)
c
▪ Preferential power supply contact
High voltage control signal
▪ Heat pump convector (option)
▪ Room thermostat (option)
▪ Shut­off valve (field supply)
▪ Domestic hot water pump (field supply)
▪ Alarm output
▪ Changeover to external heat source control
▪ Space heat operation control
CAUTION
Do NOT push or place redundant cable length in the unit.
7.6.4
To connect the main power supply
1 Connect the main power supply.
In case of normal kWh rate power supply
X5M
X6YB
X2M
30 31
X6Y
X6YA
X1M
a
1 2 3
1 2 3
Legend: see illustration below.
In case of preferential kWh rate power supply
X5M
X6Y
3 4
X6YB
X2M
30 31
X6YA
X1M
c
b
a
L N
1 2
3
L N
1 2 3
S1S
2 Fix the cable with cable ties to the cable tie mountings.
ERLQ004~008CA + EHVH04+08S18CA3VF
Daikin Altherma low temperature split
4P366226­1 – 2014.01
X1A X19A
X1A
X19A
INFORMATION
In  case  of  preferential  kWh  rate  power  supply,  the
necessity  of  separate  normal  kWh  rate  power  supply  to
indoor  unit  (b)  X2M30/31  depends  on  the  type  of
preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪ if preferential kWh rate power supply is interrupted when
active, OR
▪ if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
7.6.5
To connect the backup heater power
supply
The backup heater capacity can vary, depending on the indoor unit
model.  Make  sure  that  the  power  supply  is  in  accordance  with  the
backup heater capacity, as listed in the table below.
Backup
Backup heater
type
heater
capacity
*3V
3 kW
1 Connect  the  backup  heater  power  supply.  Use  a  single  pole
fuse for F1B.
Backup heater
Connections to
type
backup heater power
supply
F1B
3 kW 1~ 230 V
(*3V)
L N
L N
Special remark for fuses:
7 Installation
Maximum
Power supply
running current
1~ 230 V
13 A
Connections to
terminals
Installer reference guide
37